Technical Data Sheet 24k Hard Acid Immersion Gold Gold Plating Services’ Hard Acid Immersion Gold is cobalt hardened acid gold electroplating solution that will yield a relatively low stress deposit with a hardness range of 130-200 Knoop. This solution is ideally suited for printed circuit boards, contacts, reflectors, as well as heavy decorative deposits
|
||
|
Purity |
99.7%+ | |
|
Hardness |
130 - 200 Knoop | |
|
Solution Metallic Content |
.25 - 1 troy oz per gallon | |
|
Range |
||
| Operating Temperature | 90 - 105 ° F | |
| Anode to Cathode ratio | 2:1 or higher | |
| Specific Gravity | 11 - 16 Be | |
| pH (electrometric) | 4.3 - 4.8 | |
| Time to deposit 0.0001" (2.5microns) | 12 minutes @ 10 ASF | |
| Replenishment | .5 Hard Acid Gold Replenisher solution every 300 ampere minutes | |
| Filtration | Continuous | |
| Efficiency | 25- 50 % | |
| Current Density | 5 - 15 ASF | |
| Anode | 316 Stainless Steel, Platinized Columbium, Platinized Titanium or graphite | |
| Agitation | cathode movement or solution pumping | |
|
Note:
pH will slowly rise during operation and should be checked every
100-ampere minute with a glass electrode pH meter.
To lower the pH use reagent grade phosphoric acid diluted in DI
water. To raise the pH use
reagent grade potassium hydroxide dissolved in DI water. Before
using with this solution, plastic tanks, tubing, pumps, etc. should have a
5 to 10% solution of sulfuric acid allowed to remain in the tank for 24
hours. Run the acid solution
through the tank and in the filter system for 2 hours.
Drain and rinse the tank and filter thoroughly.
Repeat rinsing with fresh water until pH is above 4.5. |
||
| Read and understand MSDS sheets before using: For professional use by trained technicians only. | ||