ProLab Graphite Anode Inserts
ProLab Graphite Anode Inserts - Anode and Titanium Screw is backordered and will ship as soon as it is back in stock.
Safety and Technical Data
Safety and Technical Data
Click here to access the Safety Data Sheet
Click here to access the Technical Data Sheet
California residents: Click here for Proposition 65 warning.
We suggest reading this safety information completely before operating any of our machines. Review and understand the Safety Data Sheets (SDSs) for all the products prior to using your plating system. The SDS information should be kept in a location that will make it readily accessible in the event of accidental exposure or spillage of the product.
Using your electroplating system safely depends on following a few simple rules. While we have taken extensive measures to protect the user, there are several common sense rules that are important to follow in using your plating system.
Personal Protection
The first safety consideration is the use of proper personal protective equipment such as a face shield, safety goggles, or safety glasses. Whichever you choose, it is imperative that the solution is prevented from getting into the eyes. Should this happen, the eyes must be flushed with water and medical attention received as indicated on the Safety Data Sheet for the product that caused the exposure. We recommend the use of rubber or latex gloves to prevent contact of the solutions with the skin. It is also advisable to use chemical resistant sleeves and an apron to protect clothing, as some solutions may damage clothing. Certain processes such as electro-cleaning, activation, and other plating operations can produce corrosive vapors that may irritate the eyes, nose, throat, and skin. Use of any electroplating system should be done in a well-ventilated area. The use of a fan to disperse vapors can reduce the risk of excessive exposure to corrosive vapors.
Handling Chemicals
The chemicals you will use with your electroplating system are serious electroplating solutions that, if handled improperly, could pose a significant risk to personal health and safety. The solutions are corrosive and/or harmful if ingested. Improper use of the solutions could lead to serious injury or death. Any of the provided solutions could be harmful or fatal if swallowed in sufficient quantities. They could also cause serious chemical burns to skin if not immediately washed off after exposure. These solutions are intended to be used by responsible, trained adults. The person using the equipement or solutions should read and understand this safety information before beginning machine operation. The Safety Data Sheets (SDSs) for the chemicals that are provided with the system can be found online at www.GoldPlating.com. These sheets will inform you of many important aspects of the chemicals that you may be using.
Click Here to access Safety Data Sheets
Chemical Storage
The chemicals provided with your Gold Plating Services plating system, and the rinse water generated by using it, must be properly stored in a secure, cool location. These should not, at any time, be accessible to children or other un-authorized persons. Never store any of these solutions in un-marked containers or in any container that could lead to improper use or disposal of the solutions or rinse water. The rinse water produced by the plating operations is a hazardous material and must be collected, stored, and disposed of in accordance with all local, state, and federal laws. If you are unsure of the applicable laws, check with the local water reclamation district (sanitary sewer district), local or state environmental health, and/or the federal Environmental Protection Agency.
Electrical Hazard
In the event of failure of a machine power supply to operate as indicated in its manual, contact Gold Plating Services for recommendations on how to proceed. Do not open the power supply or plating console; there are not any user serviceable components inside. Opening the unit can revoke the warranty.
Make sure the power supply is connected to a properly grounded outlet. If the electroplating kit will be used near fixed plumbing, we recommend that the outlet have ground fault protection. Pretreatment and plating voltages are normally very low, usually less than 12 volts direct current. However, the wall adapter is connected to the supply outlet, which can expose the user to dangerous voltage if the unit is connected or handled improperly. The heater is electrically isolated and should not produce an electrical shock hazard under normal operating conditions. Never immerse the power supply or plating console in water. Immersion of either of these units could damage the electrical components and void the warranty. The AC power input cords should be maintained in good condition. The cord to the control can be replaced with any “computer style” cord if damaged. Should the white heater cord attached to the plating console become damaged, return the plating console to Gold Plating Services for replacement. When returning the plating console for repairs, do not send any chemicals, bus bars, anodes, or beakers unless directed to do so by a representative of Gold Plating Services Technical Department. Refer to the Limited Warranty at the end of this manual.
Storage of Chemicals When Not In Use
One of the most beneficial features of our electroplating kits is the ease of storing the products and solutions when not in use. If you expect to use your machine within a week or two, make sure the lids on the solution beakers are tight, which helps prevent spilling or evaporation. If you expect to store your system for a longer period, we recommend returning the solutions to their original, labeled containers.
- Frequency of use
- Exposure to contaminants
- Ongoing storage conditions
Safety Data Sheets
The Safety Data Sheets (SDSs) for our solutions are available online at www.GoldPlating.com. It is recommended to keep the SDS information for the chemicals you use in a readily accessible location.
International Customers
International Customers
Customer is responsible to pay for all customs duties and fees.
Shipping Carriers
UPS & DHL (Primary Methods Used)
FedEx and USPS (Upon Request): Please leave a note at checkout if you have a preference.
We can ship on customer carrier accounts.
A $10 handling fee will be applied to your order. Contact us directly.
Our website will calculate shipping costs, but if the final shipping cost significantly differs, we may contact you regarding a payment difference.
Products that Cannot Ship Internationally
Components in the following products are classified as LQ (Limited Quantity). Such products are required to ship via ground transport only. They CANNOT ship via air.
Solutions Include:
-
Chrome Stripper

- Wood's Nickel Strike (Can ship base, but not the ready-to-use solution. Additional chemicals required.)
- TriVal Gold Strike (Can ship base, but not the ready-to-use solution. Additional chemicals required.)
- Bright Silver NC
- Bright Acid Copper
Some of our Kits include LQ products and cannot ship internationally.
Here is a list of kits that can ship internationally WITH exceptions:
- Universal Chrome - We have an option that can ship internationally. Click here.
- Universal Plater Option 2 - This kit can be shipped internationally with the Wood's Nickel Strike Base, but not the ready-to-use solution. See product page for more details.
- JewelMaster Pro HD Option 3 & 4 - This kit can be shipped internationally with Wood's Nickel Strike Base and TriVal Gold Strike Base, but not the ready-to-use solutions. See product pages for more details.
- JewelMaster Pro HD Option 6 - Cannot ship internationally
- ProLab Modules - Any module that includes a Limited Quantity solution cannot be shipped internationally, but Wood's Nickel Strike and TriVal Gold Strike Modules can be shipped with the chemical base. See product pages for more details.
Shipping Fees & Customs:
- Buyer Responsibility: All customs fees, duties, and taxes are the sole responsibility of the buyer. They are not included in the amount paid to Gold Plating Services and must be paid directly to your local authorities or carrier.
- Estimated Rates: While we do not have exact rates for every country, in our experience, duties and taxes typically average 15% to 20% of the purchase price. We highly recommend contacting your local Customs Office to verify your country's rates before ordering.
- Refused Shipments: If you refuse a delivery after it has shipped, you will forfeit all shipping costs and will be held responsible for any return shipping fees or financial penalties incurred by the carrier.
Returned Product
What to expect if a package is returned to Gold Plating Service due to one of the following reasons:
- An incorrect address was provided by the customer
- Refusal at delivery
- Carrier was unable to contact customer for delivery
- Customer refused or failed to pay customs
Order will be refunded upon arrival and evaluation of your contents. Shipping costs and up to a 20% restocking fee will be deducted from the total amount.
Delivery and Shipping
Delivery and Shipping
Shipping Carriers Offered
USPS, UPS, FedEx, & DHL
NOTE: Can ship on customers' accounts. Orders need to be placed via phone or email. $10 handling fee applies.
Expedited Options at checkout
Cut off times are 11 AM (Fedex) & 1 PM (UPS) MST to go out the same day. LQ (Limited Quantity) items will ship separate.
- Overnight
- 2 Day
- 3 Day
Limited Quantity Products
- There is a 1x Cart Fee of $12.99
- Can only ship ground. Expedited shipping is not available
- Cannot be shipped internationally. Some solutions can be shipped as a base.
Gold Plating Services is not liable for lost, stolen, damaged, or delayed packages.
Shipping Protection Policy
- Optional Protections: Shipping insurance and signature confirmation are available at checkout to protect your order.
- Opt-Out Risk: By declining these options, you accept full responsibility for the package once it is transferred to the carrier.
- Tracking & Carrier Support: After a tracking number is issued, all delivery coordination must be managed directly with the shipping carrier.
- Liability Notice: Gold Plating Services is not liable for lost, stolen, damaged, or delayed shipments.
Shipping Insurance
$1.00 per $100 of insurance coverage. Available at checkout.
Required Signature
$6.75 at checkout
Missing or Damaged Packages
If you receive your order with missing items or in damaged condition, it must be reported to us within 10 days from when the order was received. Do not use or dispose of products or packaging. Photos are required, and damaged or incorrect items may need to be returned.
Missing, Wrong, or Damaged Item Received Click Here
Delivery Issues Click Here
Order Verification and Payment Processing
Gold Plating Services reserves the right to hold any order to confirm that payment has fully processed and cleared before shipment. This verification process typically affects first-time buyers and high-value orders. To ensure the fastest processing time and avoid potential shipping delays, customers are encouraged to complete payment via bank wire transfer, which provides the quickest confirmation.
ProLab Graphite Anode Inserts - Anode and Titanium Screw is backordered and will ship as soon as it is back in stock.
Description
Description
The ProLab cm graphite anode inserts are an economical and ideal anode for any solution requiring an anode that won't contaminate pre-treatment or plating solutions. It is optional to include the titanium hardware and screws required for mounting onto the ProLab cm titanium anode frame. The graphite anode inserts come "bagged" in a high-quality polypropylene bag to keep the solution pristine (size = 1/4" x 1" x 6"). We recommend two graphite anodes for most applications.
Solutions that require an insert anode, (platinum or graphite):
- Surface Activator
- TriVal (acid gold strike solution)
- Gold solutions (14K, 18K, 24K Bright Gold or 24K Pure Gold)
- Rhodium
- Palladium
*TITANIUM FRAME AND TITANIUM SCREW ARE NOT INCLUDED.
Check out our Plating Procedure Chart for details about our products and how to use them.
How to attach anodes to anode frame
Available Payment Methods & Associated Processing Fees
Payment we accept
3% Processing fee will be added at checkout for CC
1% ACH fee up to $15 (Contact us directly)
Wire transfers. (Contact us directly)
Associated Wire Fee : USA no additional fee. International $30 fee.



